Testing services
Equipment name: ED-XRF
Brand name: Bruker
Model name: S2 Puma
X-ray fluorescence (XRF) is the emission of characteristic “secondary” (or fluorescent) X-rays from a material that has been excited by bombarding with high-energy X-rays. Bruker S2 Puma ED-XRF irradiation apparatus offers non-destructive analytical technique used to obtain elemental composition information from different types of materials. We recommend our client to send not less than 8 grams with particle size ≤ 75 µm of each sample.
Equipment name: XRD
Brand name: Bruker
Model name: D6 Phaser
X-ray Diffraction Analysis (XRD) is a non-destructive analytical technique which can yield the unique definition of crystalline phases. Every crystal has a defined structure which is like human fingerprint, XRD can be used to characterized its structure. Spectrums produced are analyzed using DIFFRAC.EVA and ICDD PDF 5+ software that contains more the 200,000 databases of organic, inorganic, forensic material, pigments, and others. Sample in powder form must be at least 5 grams and with between the 120 µm to 212 µm range particle size. Alternatively, sample submitted in solid form must be 10 mm-20 mm in size and 5mm thickness. Thin film sample type is acceptable.
Both equipment now located in Radiation Laboratory Room of the Engineering Research Building, Curtin University Malaysia in Miri, Sarawak.
NO. |
EQUIPMENT MODEL AND BRAND |
SHORT EQUIPMENT NAME |
QUANTITY |
EQUIPMENT CONDITION CURRENT STATUS |
1 |
S2 PUMA BRUKER |
ED-XRF |
1 |
Good working condition |
2 |
D6 PHASER BRUKER |
XRD |
1 |
Good working condition |
For enquiries or quotation or request application form, please drop an email to foes.testlab@curtin.edu.my or to contact persons shown below.
Contact Person:
Staff In Charge Name: Dr. Vijay Anand Sundarrajan
Position: XRD XRF Technical Advisor and Lecturer
Email: vijay.anand@curtin.edu.my
Telephone: +60 85 630100 Ext:2486; DID: +60 85 630 254
ORCID: https://orcid.org/0000-0002-2202-4113
Google Scholar: https://scholar.google.com/citations?user=5XAPX-EAAAAJ&hl=en
Research Gate ID: https://www.researchgate.net/profile/Vijay-Sundarrajan/research
Research Interests:
- Mineralogy and Geochemistry
- Petrology
- Global Gold deposits
- Geofluids
- Research on ore minerals
- Spectroscopic study of mineral deposits
Contact Person:
Staff In Charge Name: Marilyn Andrew Anyi
Position: Technical Officer and Radiation Protection Officer
Email: marilyn.anyi@curtin.edu.my
Telephone: +60 85 630100 Ext:2717; +6016-853-2414